Page 49

CV 63
Analog Mode Motor Start Voltage

Description

CV 63 contains a value between 0 and 255 corresponding to the voltage

difference between when the decoder first powers up and when the

locomotive starts to move.

D0-D7: Analog Mode Motor Start Voltage Value

CV 63 may be set to any value between 0 and 255 corresponding to tenths of

a volt. Thus, a setting of 23 adds 2.3 volts to Tsunami’s default start voltage

of 7.5 volts.

Normally, Tsunami will power up in Analog mode around 5 volts or so and

the engine will begin moving around 7.5 volts. Under certain circumstances

you may experience a condition where the decoder cycles back and forth

between start up sounds and locomotive movement. The problem is usually

due to a poorly regulated power pack output. The sudden increase in load

due to the motor starting causes the track voltage to droop which in turn

resets the sound decoder. By increasing the setting of CV 63, you can

adjust the decoder so that when the motor starts, the track voltage will be

sufficiently high so that any droop that occurs will not turn off or reset the

decoder.