Tsunami Technical Reference

Page 73

CVs 177-189
Dynamic Digital Exhaust Control Registers

Description

These CVs control how the DDE processor modifies the sound envelope in

response to changes in the locomotive load.

CV 177 Throttle Gain

Bits 0-7:

D0:D7, DDE Throttle Gain

This CV contains a value between 0 and 255 that

specifies the DDE sensitivity to the difference between

the throttle setting and actual locomotive speed. A value

of 0 will disable this input.

Default Value:

10

Bit 7

Bit 0

D7

D6

D5

D4

D3

D2

D1

D0