Internal connection wiring diagram – Space Ray ETS Series User Manual

Page 35

Advertising
background image

Form 43343300

-34-

May 2013

INTERNAL CONNECTION WIRING DIAGRAM

INTERNAL CONNECTION WIRING DIAGRAM

INTERNAL CONNECTION WIRING DIAGRAM

INTERNAL CONNECTION WIRING DIAGRAM —

Direct Spark Ignition

Direct Spark Ignition

Direct Spark Ignition

Direct Spark Ignition

42874000 Rev. H 1/2012

G

BL

BL

BK

BK

R

W

BK

BK

R

BK

W

BK

BK

W

DRAFT

INDUCER

MOTOR

GAS VALVE

AIR SWITCH

TRANSFORMER

120V PRIMARY

24V SECONDARY

A

G

R

IGNITION MODULE

HIGH VOLTAGE

CABLE

ELECTRODE

GAP 3/16”

CONTINUE TO

ADDITIONAL

HEATERS

NEUTRAL

120V

THERMOST

A

T

GROUND

L1

L2

TERMINAL

BLOCK

FACTORY WIRING

FIELD WIRING

CONNECTION WIRING DIAGRAM

CONTROL CABINET

If any of the original wire as supplied with the

appliance must be replaced. It must be

replaced with wiring material having a

temperature rating of at least 105oC. (18

AWG. - UL / CSA 600V Type TEW)

When connecting the supply circuit to the

heater, wiring material having a minimum size

of 14 AWG and a temperature rating of at

least 90oC shall be used.

WIRE LEGEND

ENGLISH

FRANCAIS

BK

BLACK

NOIR

W

WHITE

BLANC

R

RED

ROUGE

BL

BLUE

BLEU

G

GREEN

VERT

A

AMBER

AMBRE

MONITORING LIGHTS

GND

(BURNER)

25V

FUSE 2A

JUNCTION BOX

SJO CABLE

(NOT

INCLUDED)

W

R

BK

Schéma de circuit de connexion

Circuit d'origine

Connexions client

Lampes témoins

Neutre

Terre

Vers les autres

radiateurs

Plaque à

bornes

Transformateur

bobine primaire 120ÊV

bobine secondaire 24ÊV

pressostat

Robinet à gaz

Écartement

d'électrode

4,7Êmm

Haute tension

Armoire de commande

Bloc d'allumage

Moteur

d'amorce

d'aspiration

S'il faut remplacer un fil de l'appareil d'origine,

utiliser exclusivement des fils à température

de service nominale d'au moins 105C (18

AWG. - UL / CSA 600ÊV

Type TEW).

Pour raccorder le circuit d'alimentation au

radiateur, utiliser des fils de calibre 14 AWG

ou plus à température de service nominale

d'au moins 90C.

Fusible

Bloc de jonction

Câble SJO

(non compris)

VALVE

VALVE

NOTES:

NOTES:

NOTES:

NOTES:

1.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring

material having a temperature rating of at least 105ºC. (18 Ga. CSA 600V Type TEW)

2.

When connecting the supply circuit to the heater, wiring material having a minimum size of 14 AWG and a

temperature rating of at least 90ºC shall be used.

3.

A replaceable 2-amp fuse (1-1/4” long) is fitted to the terminal block located inside the junction box

assembly.

SCHEMATIC

SCHEMATIC

SCHEMATIC

SCHEMATIC WIRING DIAGRAM

WIRING DIAGRAM

WIRING DIAGRAM

WIRING DIAGRAM —

Direct Spark Ignition

Direct Spark Ignition

Direct Spark Ignition

Direct Spark Ignition

SCHEMATIC WIRING DIAGRAM

MOT

Motor

Moteur

GL

Green Light

Témoin vert

TRANS 24V Transformer Transformateur 24ÊV

RL

Red Light

Témoin rouge

AS

Air Switch

pressostat

SM

Ignition Module

Bloc d'allumage

IG/S

Ignitor / Sensor

électrode

V

Gas Valve

Robinet à gaz

AL

Amber Light

Témoin ambre

MOT

120V

GL

TRANS

RL

AS

IG/S

AL

V

SM

42785000 Rev. C 10/04

25V GND

25V

Advertising
This manual is related to the following products: