0) specifications, 0) packing list – Space Ray ETS Series User Manual

Page 6

Advertising
background image

Form 43343300
May 2013

-5-

5.0)

SPECIFICATIONS

Model No.

Model No.

Model No.

Model No.

Btu/hr

Btu/hr

Btu/hr

Btu/hr

In

In

In

Input

put

put

put

Flue Restrictor

Flue Restrictor

Flue Restrictor

Flue Restrictor Plate

Plate

Plate

Plate

I.D. &

I.D. &

I.D. &

I.D. & Part #

Part #

Part #

Part #

Orifice Size

Orifice Size

Orifice Size

Orifice Size

Minimum *

Minimum *

Minimum *

Minimum *

Mounting Height

Mounting Height

Mounting Height

Mounting Height

Natural Gas

Natural Gas

Natural Gas

Natural Gas

Propane Gas

Propane Gas

Propane Gas

Propane Gas

@

@

@

@

Horizontal

Horizontal

Horizontal

Horizontal

@

@

@

@

45º Angle

45º Angle

45º Angle

45º Angle

ETS/ETU 40

40,000

1”

#42741040

#31

(0.120)

#49

(0.073)

10 ft.

9 ft.

ETS/ETU 50

50,000

1-1/8”

#42741030

3.3mm

(0.130)

#46

(0.081)

11 ft.

10 ft.

ETS/ETU 60

60,000

1-7/32”

#42741020

#27

(0.144)

#43

(0.089)

12 ft.

11 ft.

ETS/ETU 75

75,000

1-7/16”

#42741010

#20

(0.161)

#39

(0.099)

13 ft.

12 ft.

ETS/ETU 80

80,000

1-1/2”

#42741050

#19

(0.166)

#38

(0.102)

13 ft.

12 ft.

ETS/ETU 90

90,000

1-1/2”

#42741050

#16

(0.177)

#36

(0.106)

13 ft.

12 ft.

ETS/ETU 100

100,000

1-5/8”

#42741060

#14

(0.182)

#33

(0.113)

13 ft.

12 ft.

ETS/ETU 110

110,000

1-3/4”

#42741070

#10

(0.194)

#31

(0.120)

14 ft.

13 ft.

ETS/ETU 120

120,000

1-3/4”

#42741070

13/64

(0.203)

1/8

(0.125)

14 ft.

13 ft.

ETS/ETU 125

125,000

1-7/8”

#42741080

#5

(0.206)

#30

(0.129)

14 ft.

13 ft.

ETS/ETU 130

130,000

1-7/8”

#42741080

#4

(0.209)

3.3mm

(0.130)

14 ft.

13 ft.

ETS/ETU 140

140,000 2-1/32”

#42741090

5.5mm

(0.216)

#29

(0.136)

15 ft.

14 ft.

ETS/ETU 150

150,000 2-1/32”

#42741090

5.7mm

(0.224)

#28

(0.140)

15 ft.

14 ft.

ETS/ETU 160

160,000

2-1/4”

#42741100

5.8mm

(0.228)

#27

(0.144)

15 ft.

14 ft.

ETS/ETU 175

175,000

2-1/4”

#42741100

“C”

(0.242)

3.8mm

(0.150)

15 ft.

14 ft.

ETS/ETU 180

180,000

2-1/4”

#42741100

“C”

(0.242)

#24

(0.152)

18 ft.

17 ft.

ETS/ETU 200

200,000

2-3/8”

#42741130

“F”

(0.257)

#21

(0.159)

18 ft.

17 ft.

ETS/ETU 225

225,000

2-1/2”

#42741140

6.9mm

(0.272)

#18

(0.170)

20 ft.

19 ft.

ETS/ETU 250

250,000

2-3/4”

#42741150

“K”

(0.281)

4.5mm

(0.177)

20 ft.

19 ft.

* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.

Type

Type

Type

Type

Gas

Gas

Gas

Gas

Gas Pipe

Gas Pipe

Gas Pipe

Gas Pipe

Connection

Connection

Connection

Connection

1

1

1

1

Tube

Tube

Tube

Tube

Diameter

Diameter

Diameter

Diameter

Flue

Flue

Flue

Flue

Connection

Connection

Connection

Connection

2

2

2

2

Fresh Air

Fresh Air

Fresh Air

Fresh Air

Connection

Connection

Connection

Connection

Electrical

Electrical

Electrical

Electrical

Supply

Supply

Supply

Supply

Current

Current

Current

Current

Rating

Rating

Rating

Rating

Natural

or Propane

½” MPT

(Male)

4”

4” Round

6” Round

120 Volt, 60Hz,

1 Phase

2.6 Amp

1

ETS/ETU 225 and 250 require a minimum 3/4” nominal ID flexible gas connector.

2

ETS/ETU 180-250: 6” round. See Section 17.0) for vent sizes and limitations

Fuse

Fuse

Fuse

Fuse Rating:

Rating:

Rating:

Rating:

Ignition System (direct spark):

Ignition System (direct spark):

Ignition System (direct spark):

Ignition System (direct spark):

In-line: 2 Amp 250V

(for 24V Circuit)

30 second pre-purge period

6.0)

PACKING LIST

A.

A.

A.

A.

EEEETS

TS

TS

TS/

//

/E

E

E

ETU

TU

TU

TU 40

40

40

40----250 Control/Draft Induce

250 Control/Draft Induce

250 Control/Draft Induce

250 Control/Draft Inducer Package

r Package

r Package

r Package

Part Description

Part Description

Part Description

Part Description

QTY

QTY

QTY

QTY

Control Box Assembly .............................................................................................................................. 1
Draft Inducer & Junction Box Assembly ................................................................................................ 1
Flue Restrictor Plate (See Section 5.0) for plate I.D. and part no.) ................................................... 1
4” x 6” Starting Collar

1

(#42892009) Supplied with ETS/ETU 180-250 ........................................ 1

Control Fastener Kit (#42907110) ....................................................................................................... 1

Containing: #8-32 Screws & Nuts (#02166010 & #02127030) .......................................... 2

¼ - 20 Locknuts (#02167010) .............................................................................. 6

Tube Flange Gasket (#42921000) ........................................................................ 2

Draft Inducer Flange (#44015251) ...................................................................................................... 1
Installation & Operation Instructions (#43343300) .......................................................................... 1
Gas connector, 5/8” OD x 36” (#30302360)

2

................................................................................... 1

1

4-inch Starting Collar (#40504020) supplied with ETS/ETU 40-175 models.

2

ETS/ETU 225 and 250 models using Gas Connector, 1” OD x 36” (#30302361)

Advertising
This manual is related to the following products: