4 comms switch map example 2 – Sundance SMT329 User Manual

Page 15

Advertising
background image

This example duplicates the default connectivity of the SMT328, and is loaded in the flash
during SMT329 production, filename “s329map.txt” :

SMT329MAPCAB012345D78

SUNDANCE SMT329 STANDARD COMMS PORT MAP MIMICS SMT328

DATE: 17-DEC-06

COMPANY: SUNDANCE

AUTHOR: SEC

Connect SMT329 to mimic a standard SMT328

Entry Value Description

1 12 = 0xC T1C3 (RTI) to VXC1 (RTO)

2 10 = 0xA T1C4 (RTI) to T4C1 (RTO)

3 11 = 0xB T1C5 (RTI) to T4C2 (RTO)

4 0 = 0x0 T2C3 (RTI) to T1C0 (RTO)

5 1 = 0x1 T2C4 (RTI) to T1C1 (RTO)

6 2 = 0x2 T2C5 (RTI) to T1C2 (RTO)

7 3 = 0x3 T3C3 (RTI) to T2C0 (RTO)

8 4 = 0x4 T3C4 (RTI) to T2C1 (RTO)

9 5 = 0x5 T3C5 (RTI) to T2C2 (RTO)

10 13 = 0xD T4C3 (RTI) to VXC2 (RTO)

11 7 = 0x7 T4C4 (RTI) to T3C1 (RTO)

12 8 = 0x8 T4C5 (RTI) to T3C2 (RTO)

The map file is stored in the flash in ascii

and has a keyword identifier immediately before the map data of
"SMT329MAP"

This is the map which is duplicated at the top of the file:

SMT329MAPCAB012345D78

-END-

The very first line begins with the map keyword “SMT329MAP“, although it can appear
anywhere in the text. This is immediately followed by “CAB012345D78” which is the actual
map. The descriptive text which follows explains each map entry.

4.2.2.4 Comms Switch Map Example 2

User Manual SMT329

Page 15 of 52 Last

Edited:

09/02/2007

10:58:00

Advertising