4.2.2.6 Comms Switch Map Diagnostic Port and Error Detection

An 8 bit diagnostic read only port is provided by the Spartan3. This port operates by setting
an 8 bit register address, then reading the 8 bit register value. The following registers are
currently defined:

Register
address

Description

00

Map entry 0 + 0x80 if transmitting

01

Map entry 1 + 0x80 if transmitting

02

Map entry 2 + 0x80 if transmitting

03

Map entry 3 + 0x80 if transmitting

04

Map entry 4 + 0x80 if transmitting

05

Map entry 5 + 0x80 if transmitting

06

Map entry 6 + 0x80 if transmitting

07

Map entry 7 + 0x80 if transmitting

08

Map entry 8 + 0x80 if transmitting

09

Map entry 9 + 0x80 if transmitting

0A

Map entry A + 0x80 if transmitting

0B

Map entry B + 0x80 if transmitting

0C 0x0C

0D 0x0D

0E 0x0E

0F 0x0F

10

RTO 0 is connected to this RTI + 0x80 if transmitting

11

RTO 1 is connected to this RTI + 0x80 if transmitting

12

RTO 2 is connected to this RTI + 0x80 if transmitting

13

RTO 3 is connected to this RTI + 0x80 if transmitting

14

RTO 4 is connected to this RTI + 0x80 if transmitting

15

RTO 5 is connected to this RTI + 0x80 if transmitting

16

RTO 6 is connected to this RTI + 0x80 if transmitting

17

RTO 7 is connected to this RTI + 0x80 if transmitting

18

RTO 8 is connected to this RTI + 0x80 if transmitting

19

RTO 9 is connected to this RTI + 0x80 if transmitting

User Manual SMT329