DIU/DIM Details

7-10

Verilink

Figure 7-12 T1 Multiplexer (CSU/DSU) Operation

Drop-and-Insert

Mode

The CSU of an SCC, NCC ,or TAC can also operate with DIUs in a
drop-and-insert mode. This allows the CSU to transmit a
combination of voice (VF) and high-speed data over the T1 network.
The CSU provides drop-and-insert toward either the network or the
equipment in a full-duplex, unidirectional transmission mode.

Toward Network

Figure 7-13 shows a CSU drop-and-insert configuration toward the
network. The incoming signal from the customer’s DS1 equipment
is applied to a multiplexer in the CSU. The multiplexed data from
the DIUs is also routed to this multiplexer over the data bus A on
the shelf backplane. This data occupies the DS0 channel time slots
assigned by the user to the DIUs. The T1 aggregate signal is then
applied by the multiplexer to the network.

DATA
EQPT

DIU

NCC or TAC

DIU DATA BUS A, B, or C on
SYSTEM SHELF BACK PLANE

DATA
EQPT

DATA
EQPT

DATA
EQPT

DIU

XMT DATA

DIU XMT CLOCK

XMT FRAMING

RCV DATA

DIU RCV CLOCK

RCV FRAMING

XMT DATA

DIU XMT CLOCK

XMT FRAMING

RCV DATA

DIU RCV CLOCK

RCV FRAMING

T1

AGGREGATE

AND SIGNAL

PROCESSING

CIRCUITS

TO/FROM

NETWORK