Westermo GDW-11 User Manual

Page 35

Advertising
background image

Network service commands 35

6615-2220

NOTE:

… If an incoming call occurs during a PLMN list request, the operation is aborted

(+CME ERROR: 520) and the unsolicited RING appears.

… If SPN (Service Provider Name) is present in the SIM, it will be returned in both long

and short alphanumeric <oper> fields. The string in the “short” field will be the SPN
truncated to the appropriate character number.

Parameters:

<mode>

0:

automatic (default value)

1: manual

2:

deregistration ; ME will be unregistered until <mode>=0 or 1 is selected.

3:

set only <format> (for read command AT+COPS?)

4:

manual / automatic (<oper> shall be present), if manual selection fails, automatic
mode is entered.

<format>

0:

long alphanumeric format <oper>

1: short

alphanumeric

format

<oper>

2:

numeric <oper> (default value) <stat> status of <oper>

<stat>

0: unknown

1: available

2: current

3: forbidden

<oper>

Operator identifier (MCC/MNC in numeric format only for operator selection). The long
alphanumeric format can be up to 16 characters long (see appendix 18.12 for operator
names description, field is “Name”). The short alphanumeric format can be up to 8 char-
acters long.