Conversion kit instructions, Dvie22 – Archgard 27-DVIE22N User Manual

Page 14

Advertising
background image

27-DVIE22

14

CONVERSION KIT INSTRUCTIONS

The installation is not proper and complete until operation of the converted appliance is checked as specified in the instructions sup-

plied with the kit. Refer to appliance owner’s manual or product data plate for proper inlet and manifold pressure adjustments and ori-
fice sizing.

PREPARE THE FIREPLACE

Remove the surround, glass door assembly, logs/media and brick/panels (if applicable).

Remove the burner side brackets and the front ember ledge. The ledge lifts up and out.

Remove burner . Three screws along the top edge of the burner secure it to in place.

KIT NUMBERS:

27-CKELP for LP gas and 27-CKENG for Natural Gas

KIT INCLUDES:

1- Gas conversion label (303-0128)

1- Burner orifice (301-0068) (#54 DMS for LPG) (#43 DMS for NG)

1- Instruction Sheet

1- SIT 885 Valve conversion regulator c/w instructions & gas type label (0.907.012 ) LPG

(0.907.013 ) NG

PILOT CONVERSION

Using a 7/16” wrench and loosen the pilot hood 1/4
turn. Slide the tab at the bottom of the orifice hood all

the way so the red side (propane) with the hole in it is
showing. Tighten the pilot hood back up so that it is
lined up with the two probes on both sides of the pilot

assembly.

F O R Y O U R S A F E T Y

SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE BEFORE BEGINNING THE GAS

CONVERSION

Remove the burner orifice using a 1/2” wrench. Replace with the

orifice supplied with the conversion kit. Use a small amount of
pipe sealant on the threads of the orifice holder.

Fig. 14-A

LP has hole
and red dot

Natural Gas

Fig. 14-B

Wrench here

Fig. 14-C

W A R N I N G

The conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable

codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explo-

sion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life. The qualified service

agency is responsible for proper installation of this kit.

I M P O R T A N T

This fireplace is Natural gas ready. If converting to LP gas, follow instructions below