Connecting the switch to a –48 VDC power source

CAUTION:

To connect the switch to a –48 VDC power source, you can only use a DC power cord provided by H3C.

To connect a DC power cord to a –48 VDC power source, identify the positive (+) and negative (-) marks
on the two wires of the power cord to avoid connection mistakes.

To connect the switch to a –48 VDC power source:

1.

Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.

2.

Correctly orient the plug at one end of the cable with the power receptacle on the power module,
and insert the plug into the power receptacle. See callout 1 in

Figure 23

.

If you cannot insert the plug into the receptacle, re-orient the plug rather than use excessive force
to push it in.

3.

Tighten the screws on the plug with a flat-blade screwdriver to secure the plug in the power
receptacle. See callout 2 in

Figure 23

.

4.

Connect the two wires at the other end of the power cord to a –48 VDC power source.

Figure 23 Connecting the DC power cord to the S5130-28F-EI switch

Connecting the switch to an RPS

CAUTION:

To connect the switch to an H3C RPS, you can only use the power cord that is provided with the RPS.

To connect the switch to an RPS:

1.

Correctly orient the plug with the power receptacle on the power module, and insert the plug into
the receptacle (See callout 1 in

Figure 23

).

If you cannot insert the plug into the receptacle, re-orient the plug rather than use excessive force

to push it in.

2.

Tighten the screws on the plug with a flat-blade screwdriver to secure the plug in the RPS receptacle.
See callout 2 in

Figure 23

.