Removing an interface card, Installing and removing a dedicated cx4/sfp+ cable, Installing a dedicated cx4/sfp+ cable – H3C Technologies H3C S5120 Series Switches User Manual

Page 27: Callout 1 in, Figure 23

Advertising
background image

19

Figure 23 Installing an interface card (2)

NOTE:

Keep the removed filler panel properly for future use.

When tightening the fastening screws at both sides of the interface card with a screwdriver or an electric
screwdriver, make sure the torque is not bigger than 0.4 N-m.

Removing an interface card

CAUTION:

When installing or removing an optional interface card, follow these guidelines:

Do not touch the surface-mounted components directly with your hands.

Do not use too much force in the operation.

After removing an interface card, if no new module is to be installed, install the filler panel as soon as
possible to prevent dust and ensure the normal ventilation in the switch.

To remove an interface card:

1.

Wear an ESD-preventive wrist strap, and make sure it makes good skin contact and is well
grounded.

2.

Use a Phillips screwdriver to loosen the captive screws at both sides of the interface card until all
spring pressure is released.

3.

Pull the interface card towards you along the guide rails, until it completely comes out of the switch
chassis.

Installing and removing a dedicated CX4/SFP+ cable

Installing a dedicated CX4/SFP+ cable

Make sure you have installed a CX4/SFP+ interface card before installing dedicated CX4/SFP+ cables.

1

2

2

Advertising
This manual is related to the following products: