Enabling trap – H3C Technologies H3C MSR 50 User Manual

Page 18

Advertising
background image

10

Step Command

Remarks

5.

Enter interface view.

interface interface-type
interface-number

N/A

6.

Configure the minimum

interval for receiving BFD
echo packets.

bfd min-echo-receive-interval
value

Optional.
For more information, see the

description of the Required Min
Echo RX Interval
field in "BFD

packet format."

7.

Configure the minimum
interval for transmitting BFD

control packets.

bfd min-transmit-interval value

Optional.
For more information, see the
description of the Desired Min TX

Interval field in "BFD packet

format."

8.

Configure the minimum

interval for receiving BFD
control packets.

bfd min-receive-interval value

Optional.
For more information, see the

description of the Required Min RX
Interval
field in "BFD packet

format."

9.

Configure the detection time
multiplier.

bfd detect-multiplier value

Optional.
For more information, see the
description of the Detect Mult field

in "BFD packet format."
5 by default.

10.

Configure the authentication
mode on the interface.

bfd authentication-mode { md5
key-id
[ cipher ] key | sha1 key-id
[ cipher ] key | simple key-id

[ cipher ] password }

Optional.
By default, the interface does not
authenticate BFD packets.

In

Figure 1

, if you configure the Desired Min TX Interval as 100 milliseconds, Required Min RX Interval as

300 milliseconds, and Detect Mult as 5 on Router A, and then configure the Desired Min TX Interval as

200 milliseconds, Required Min RX Interval as 400 milliseconds, and Detect Mult as 10 on Router B:

The actual transmitting interval on Router A is 400 milliseconds, which is the greater value between
the minimum interval for transmitting BFD control packets on Router A (100 milliseconds) and the

minimum interval for receiving BFD control packets on Router B (400 milliseconds).

The actual transmitting interval on Router B is 300 milliseconds, which is the greater value between
the minimum interval for transmitting BFD control packets on Router B (200 milliseconds) and the

minimum interval for receiving BFD control packets on Router A (300 milliseconds).

The actual detection time on Router A is 3000 milliseconds, which is 10 × 300 milliseconds (Detect
Mult on Router B × actual transmitting interval on Router B).

The actual detection time on Router B is 2000 milliseconds, which is 5 × 400 milliseconds (Detect
Mult on Router A × actual transmitting interval on Router A).

Enabling trap

When the trap function is enabled on the BFD module, the module will generate trap messages at the

notifications level to report the important events of the module. The generated trap messages are sent to