Troubleshooting, Power supply failure, Configuration terminal problems – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 36: No terminal display, Garbled terminal display

Advertising
background image

30

Troubleshooting

Power supply failure

If the device cannot be powered on and the system status LED PWR is off, verify the following items:

The external AC power system is correctly working.

The AC power cord is securely connected to the device.

The power cord is in good condition.

NOTE:

If the problem persists, contact H3C Support.

Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting information

when the device is powered on. If the setup is incorrect, the configuration terminal either displays nothing
or displays garbled text.

No terminal display

If the configuration terminal displays nothing when the device is powered on, verify the following items:

The power supply is supplying power to the device.

The console cable is correctly connected.

The terminal settings are correct.

Garbled terminal display

If terminal display is garbled, verify that the following settings are configured for the terminal, for

example, HyperTerminal:

Baud rate—9600

Data bits—8

Parity—none

Stop bits—1

Flow control—none

Emulation—VT100

Advertising
This manual is related to the following products: