Displaying the operating state of a power module, Configuring the exception handling method, Configuration procedure – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 45

Advertising
background image

39

Fan 1 State: Normal

Fan 2 State: Normal

Fan 3 State: Normal

Fan 4 State: Normal

Table 10 Command output

Field Description

Fan 1

Number of the fan.

State

Fan state:

Normal—The fan is operating correctly.

Absent—The fan is not in position.

Fault—The fan has failed.

Displaying the operating state of a power module

Use the display power command to display the operating state of a power module.

<H3C>display power

Power 1 State: Normal

Power 2 State: Absent

Table 11 Command output

Field Description

Power 1, 2

Number of the power module.

State

Power module state:

Normal—The power module is operating correctly.

Absent—The power module is not in position.

Fault—The power module has failed.

Configuring the exception handling method

Configuration procedure

You can configure the device to handle system exceptions (such as system instruction faults, invalid

addresses, data overflow, null pointers, and division by zero operations) by using one of the following

methods:

Reboot—The device automatically reboots to recover from the error condition.

Maintain—The device stays in the error condition so you can collect complete data for diagnosis,

including error messages. You must manually reboot the device.

To configure the exception handling method:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

Advertising
This manual is related to the following products: