GUIDE TO INSTALLATION AND OPERATION

ADC-1101 | 3

2 Installation

2.1 Unpacking


The following items should be included in the ADC-1101 package:

• ADC-1101 CAV-to-SDI Converter

• ADC-1101-SRP rear panel

• User

manual


2.2 Installation in the Densité frame


The ADC-1101 must be mounted in a DENSITÉ frame. The installation includes both the ADC-1101
module, and the rear panel module. It is not necessary to switch off the frame’s power when installing or
removing the card.

When the ADC-1101 is used in conjunction with an audio module such as the UAP-1783, the ABUS flat
cable must be installed between the ABUS connectors located on the front card edges (see section 1.4).

Note: for a two card installation, use the two end connectors of the flat cable and leave the

middle one unplugged.


Detailed instructions for installing cards and their associated rear panels in the Densité frame are given in
the Densité Frame manual.

2.3 Connection


All video connections are made on the rear panel:

• Connect the CAV inputs to the three BNC connectors marked CAV IN
• Two SDI outputs are available on BNC connectors.


Component analog input formats supported by the ADC-1101:

525 formats

625 formats

GBR without setup

GBR

GBR with setup

EBU

SMPTE Beta

Beta without setup

Beta with setup


ADC-1101-SRP

CA
V I
N

G/Y

B/B-Y

R/R-Y

SDI OUT

2

1