Appendix B Legacy systems

Configure MPEG encoder: Single-channel encoder

This page configures the parameters the encoder uses when it creates the MPEG
proxy assets.

Test: Encoder stand-alone stage

The following test exercises system functionality exclusive to the basic
configurations for the single-channel encoder. A successful test verifies that the basic
configurations are correct.

Test description: A short test clip (high-res) is recorded on the Profile Media Server,
while at the same time the low-res proxy asset is created on the NAS.

NOTE: Run this test only in the stand-alone stage, with machines that have not yet
been added as managed devices (as in the + Server stage). Once the server is
connected, this test can result in corrupt database records.

Run the test as follows:

1. Make sure that the system is not in use.

NOTE: Running these tests will tie up a channel and could collide with commands
from the Ingest Schedule page. Inform operators that they must not use the
channels under test.

2. Click

Start | Programs | Thomson | Event Viewer

. Event Viewer opens.

B

a

sic

A

d

v

ance

d

D

o not

mo
di

fy

http://root-nb-enc-n:280

Single Channel Encoder

MPEG Encoder

!

Leave at default of 1000000.

!

Leave at default of 0. Modify only to debug server/encoder timecode problems.

!

Select

Composite

!

Select fields per second:

FPS_5994

for drop-frame NTSC,

FPS_60

for

non-drop-frame NTSC,

FPS_50

for PAL.

!

The MPEG encoder audio output. Adjust to calibrate Advanced Edit audio, or
to improve the quality of the desktop audio (i.e. if the source is 'too hot')

! !

Saves changes. Changes are lost if you leave the configuration page without
updating.

Always click

Update…

buttons after making changes

To put changes into effect, start or restart the Thomson Ingest Control service