Operation – Grass Valley Kalypso Emergency Bypass Option User Manual
Page 10
10
Kalypso Emergency Bypass Option Instruction Manual
Operation
Figure 4. Local Aux Panel Emergency Bypass Controls
The
Bypass Enable
button, when pressed with
Bypass Deleg
held down,
enables and disables emergency bypass mode. The
Bypass Enable
button illu-
minates when in bypass mode.
Note
If a BYPASS KEYER NOT ENABLED message appears you need to turn on the
option in the Eng Setup - Emg Bypass menu (
Enable
touch button). Enabling
the Emergency Bypass option in this menu is different from enabling the
operating mode itself on the Local Aux panel.
The
Bypass Deleg
button, besides being used to enable bypass mode above,
is used to delegate the Source Selection buttons to control the Background,
Keyer 1, or Keyer 2 buses for source selection (see below).
Pressing the
Key 1
or
Key 2
button mixes that key on or off on the bypass
program output. When
Bypass Deleg
is held down, pressing and releasing
the
Key 1
or
Key 2
button delegates the Source Selection buttons to that keyer
bus.
The Source Selection buttons are used (when the
Bypas Deleg
button is on) to
select the Background, Key 1, or Key2 sources, depending on the current
bus delegation (see above). The names of the currently available sources
are displayed on the middle source name display. The name of the cur-
rently selected background source is also displayed above the
Bypass Deleg
button.
Operation
The Emergency Bypass system operates with Kalypso Release 6.0 and
higher software.
Emergency
Bypass
Control
Source
Selection
Kalypso Source
Name Displays
Current Background
Name Display
0721_07_61_r0
Bypass Active
Assign
Key
1
Key
2
Bypass
Deleg
Bypass
Enable