Maintenance

Bypass Relay Module

Indicator LEDs

The Emergency Bypass Relay module (

Figure 12

) has a single Power LED,

and two operating mode LEDs above and below the mode switch. The top
red LED indicates the module is in bypass operation. The lower green LED
indicates normal (non-bypass) operation.

Figure 12. Bypass Relay Module

Relay Module Switch

The three position switch (SW 1) can be used to change module operating
modes. The up position forces bypass operation, and the bottom position
forces normal (non-bypass) operation. The center

Remote

position permits

remote mode switching from the Local Aux panel.

Breakout Cable

The breakout Y cable (

Figure 13

) used between the Local Aux panel and

Emergency Bypass frame includes a BNC connector, which is used for
contact closure.

Figure 13. Breakout Cable and Pin Connections

SW1 – three position switch
(center position REMOTE)

PWR

BYPASS

NORMAL

8121_01_02

J1

DB-9

Female

P1

DB-9

Male

P2

BNC

8121_01_03_r1

From

To

Note

J1-1

P1-5

Use cable drain wire

J1-2

P1-2

Twisted pair

J1-7

P1-7

J1-4

P2-Center

BNC connector

J1-6

P2-Shield

J1-3

P1-3

Twisted pair

J1-8

P1-8