Maintenance, Bypass frame monitor module, Indicator leds – Grass Valley Kalypso Emergency Bypass Option User Manual

Page 23

Advertising
background image

Kalypso Emergency Bypass Option Instruction Manual

23

Maintenance

Maintenance

Bypass Frame Monitor Module

Indicator LEDs

The Bypass Frame Monitor Module provides indicator LEDs on the front
of the module (visible when fan front cover is removed) that report alarm
conditions and module power status. The front edge of the Bypass Frame
Monitor Module is shown in

Figure 10

.

Figure 10. Bypass Frame Monitor Module Front View

The possible LED status and conditions indicated are shown in

Table 1

.

Table 1. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

Power

(green)

Off

Power is off or onboard regulator has failed

On continuously

Module is powered

PS2

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 2 is present and reporting an alarm condition

PS1

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 1 is present and reporting an alarm condition

Fan (red)

Module Health (red)

PS1 (red)

PS2 (red)

Temperature (red)

S1

8

7

6

5

4

3

2

1

Power (green)

Fault detected (red)

Module Health Inhibited (yellow)

Configuration DIP switch S1

0636 -16

Red = Fault
Green = OK
Yellow = Mode Active

LED Color Key

Advertising