Maintenance

Enabling Alarms and Fan Speed Control Option

The Bypass Frame Monitor Module has an eight position DIP switch (S1)
that enables or disables the alarm functions and the variable fan speed
function, same as a standard 8900 Frame Monitor module. In addition, an
RS-422 setting used only by the Bypass module is available, but must be set
to the normal position.

Refer to

Figure 10

for the location of S1 and

Table 2

for the possible settings.

FAN

(red)

Off

Normal operation or alarm disabled

On continuously

One or more fans in the front cover assembly is not rotating

MOD

(red)

Off

Normal operation or alarm disabled

On continuously

Module health bus is not disabled and one or more modules is reporting an internal fault

Flashing

One or more modules is reporting a data error

INHIB

(yellow)

Off

Normal operation or alarm disabled

On continuously

A non-compliant module in the frame has disabled the module health bus

FAULT

(red)

Off Normal

operation

On continuously

One or more of the onboard fault LEDs is illuminated or flashing

Table 2. Configuration DIP Switch Settings

Segment

Left Position (open)

Right Position (closed)

1

PS1 Fault Reporting Enabled

PS1 Fault Reporting Disabled

2

PS2 Fault Reporting Enabled

PS2 Fault Reporting Disabled

3

Overtemp Fault Reporting Enabled

Overtemp Fault Reporting Disabled

4

Fan Fault Reporting Enabled

Fan Fault Reporting Disabled

5

Module Fault Reporting Enabled

Module Fault Reporting Disabled

6

Fan Speed Controlled by Temperature

Fan Speed Fixed at Maximum

7

Not Used

8

RS-422 Normal

RS-422 Reversed

a

a

Emergency Bypass does not operate with a reversed setting.