Maintenance

Bypass Keyer Module

Indicator LEDs

The Bypass Keyer module has LED indicators above the rotary switch
(

Figure 11

).

Figure 11. Bypass Keyer Module

The possible LED status and conditions indicated are shown in

Table 1

.

Table 1. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

FAULT

(red)

Off Normal

operation

On continuously

Module FPGA is not configured or fails to configure

COMM

(yellow)

Off

-

Flickers

Communications activity under way

CONF

(yellow)

Off

-

On continuously

Module is being configured

PWR

(green)

Off

Power is off or onboard regulator has failed

On continuously

Module is powered

625

(green)

Off

-

On continuously

625 line reference is detected

LOCK

(red)

Off

-

On continuously

Module has acquired lock on reference input

REF

PRESENT

(red)

Off

Reference signal not detected

On continuously

Reference signal detected

FUNCTION – rotary switch
(1-Shaped, 2-Unshaped)

SW1 – actuator toggle switch

JP3 – jumper required on right

CONF
PWR

COMM

FAULT

REF PRESENT

LOCK

625

JP4

JP3

JP2

JP1

8121