Installation, Sms 7000 router requirements, Encore router requirements – Grass Valley Kalypso Emergency Bypass Option User Manual

Page 12: Install emergency bypass frame

Advertising
background image

12

Kalypso Emergency Bypass Option Instruction Manual

Installation

2.

The transition rate for each key is determined during configuration. A
transition rate of zero causes a cut.

Installation

Note

Each Grass Valley router control system can control a wide variety of
matrices. The type of matrix controlled does not affect operation of the
Kalypso Emergency Bypass option.

SMS 7000 Router Requirements

A CIF (communication interface) Module Option must be installed
with its Serial Mezzanine in position 1 of the option module to allow
the SMS 7000 to communicate using native protocol over a serial line.

Encore Router Requirements

An SIO ISA Mezzanine must be installed for serial communications.

Install Emergency Bypass Frame

The Emergency Bypass frame ships either with the modules pre-installed,
or with the modules packaged separately.

1.

Install the Emergency Bypass frame in any suitable rack.

2.

If the modules were packaged separately, remove the front cover and
insert the modules into the frame. For cooling efficiency, the modules
should be placed in the following slots:

a.

Insert the Bypass Relay module in slot 7.

b.

Insert the Bypass Keyer module in slot 8.

c.

Insert the Bypass Frame Monitor module into the smaller control
slot 11.

3.

Connect the Emergency Bypass frame power cords, using different line
sources if redundant power supplies are being used.