Installation – England's Stove Works 25PAH User Manual

Page 13

Advertising
background image

13

IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR

DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

INSTALLATION 

 

Approved Venting Method 3: Existing Chimney System 

 

 Using an existing masonry or factory built chimney for 

venting is the only other acceptable method for 
venting this pellet unit. 

 Use Type L or Type PL venting pipe until entering the 

existing chimney.  Use the appropriately sized adapter 
when transitioning from the pellet vent pipe to the 
masonry or factory built thimble and be certain that 
the adapter is sealed tightly to both the pellet venting 
system and the existing chimney. 

 Before using an existing chimney, be certain it is in 

good condition (A chimney sweep inspection is highly 
recommended).  Also, make sure the chimney meets 
the minimum standards listed in NFPA 211 (A 
chimney professional can confirm this upon 
inspection). 

 If connecting this stove to a factory built chimney, it 

may ONLY be a 6” flue, UL103 HT venting system (ULC 
S629 if Canada).  Connection to any other factory 
built chimney may result in a poorly operating or 
dangerous stove installation. 

 When connecting to an existing masonry chimney, the cross‐sectional area of the flue must 

be considered.  A chimney with a flue larger than 6” round (28.27 sq. in.) may require 
relining with an approved pellet stove chimney lining system. 

 Use an appliance collar where the pellet vent connects to the exhaust output of the pellet 

stove and attach the appliance collar to the exhaust blower output using three sheet metal 
screws.  

 Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is 

leak free (Check with the specific pipe manufacturer’s instructions before doing so). 

 If the pellet vent pipe being used is not a “Twist Lock” system, three (3) sheet metal screws 

are required at each pipe joint. 

 Connect the pellet stove to outside combustion air using the kit included with your stove or 

using an alternative method, as described in the “Outside Air” section, on page 15. 

 

Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as
plans for each individual installation. Please follow all venting system requirements, maintain the required clearances
to combustibles, and follow all local codes.

For high altitude installations (above 4,000
ft.), the vent pipe should be increased from

3-inch (3”) to four-inch (4”).

Advertising
This manual is related to the following products: