Thermostat operation – England's Stove Works 25PAH User Manual

Page 22

Advertising
background image

22

IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR

DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

THERMOSTAT OPERATION 

Thermostat Installation 

1. Unplug the unit and remove the back panel of the stove. 

2. Locate the thermostat connect block, labeled J18, on the rear of the control board, near 

the bottom (See image below and pg. 37 of this manual for a control board diagram).  It 
will have a small wire “jumper” installed in it from the factory.  This jumper bypasses the 
thermostat and should be saved. 

3. Loosen the two screws using a small slotted “jewelers” screwdriver and remove the 

“jumper.” 

4. Insert the two thermostat wires in place of the “jumper” and retighten the screws. 

5. Reinstall the back panel and mount the thermostat; the control board automatically 

reads the thermostat and your stove is now ready for thermostat operation. 

Connect 

thermostat 

wires here 

(J18) 

Advertising
This manual is related to the following products: