REPLACING COMPONENTS 

Vacuum Sensor 

1.

Before beginning any component 
replacement, be certain the unit is 
unplugged and thoroughly cooled 
down.  

2.

Remove the exhaust outlet cover 
plate and rear panel of unit. 

3.

Locate the vacuum sensor as shown 
in the diagram below. 

4.

Disconnect the stove wiring harness 
and vacuum hose from the vacuum 
sensor, taking note of where 
connections were made. 

5.

Remove the two screws which hold 
the vacuum sensor to the vacuum 
sensor bracket, using a Phillips screw 
driver. 

6.

Installation is the reverse of 
removal; be absolutely certain the 
wires and vacuum hose are 
connected according to the wiring 
diagram in this manual. 

Igniter 

1.

Before beginning any component 
replacement, be certain the unit is 
unplugged and thoroughly cooled 
down.  

2.

Remove the exhaust outlet cover 
plate and rear panel of unit. 

3.

Locate the igniter as shown in the 
diagram below. 

4.

Disconnect the igniter wiring from 
the control board and use a 5/16” 
wrench to remove the igniter 
retaining screw. 

5.

Loosen the allen set screw (1/8” 
allen wrench) and remove the old 
igniter cartridge. 

6.

Install the new igniter in the igniter 
tube, retighten the set screw and 
reinstall the assembly into the stove.  
Be certain to reconnect the new 
igniter wires to the circuit board 
before reassembly. 

 
 
 
 