IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR

DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

YEARLY MAINTENANCE 

Exhaust Blower Cleaning 

Although the exhaust blower and blower housing were designed to minimize ash build‐up, 
some fly‐ash will still accumulate there throughout the burning season.  The amount and type 
of ash will depend on the type of pellets and venting system, but generally this accumulation 
will be mild.  If, when cleaning the exhaust blower, a large accumulation of fly‐ash is found, 
cleaning the exhaust blower and housing should be performed monthly or bimonthly to 
prevent this excess buildup. 

Instructions 

 Before beginning the exhaust blower cleaning procedure, be certain the unit is 

unplugged and thoroughly cooled down. 

 Loosen and remove the 5/16” screw which secures the exhaust blower access door to 

the unit. 

  Once the door is open, the exhaust blower will be clearly visible. 
 Disconnect the venting system from the exhaust blower just enough that you will be 

able to remove the exhaust blower from the stove. 

 Unplug the two wires which connect the stove wiring harness to the exhaust blower 

using the quick connect plugs. 

 Loosen and remove the 5/16” screw, on the top of the exhaust blower output 

connection, which holds the thermal sensor to the exhaust blower. 

 Loosen the five (5) 5/16” self‐drilling screws which hold the exhaust blower to the 

exhaust blower tube; a 12” socket extension will likely be necessary to reach all of the 
screws. 

 Lift the exhaust blower up and out of the stove.  The gasket which seals the exhaust 

blower to the exhaust blower tube is fragile, so take extra care when removing the 
blower.  Even when being careful, though, it is easy to tear this fragile gasket, and since 
an airtight seal is crucial here, it is best to replace this gasket (Part # ‐ PU‐CBG) every 
time the exhaust blower is removed. 

 With the exhaust blower removed, use a utility vacuum to remove any ash accumulation 

in the exhaust blower tube. 

 Use a soft paint brush and carefully remove any ash accumulation from the inside of the 

exhaust blower, and from the exhaust blower fan blade. 

 Inspect the exhaust blower motor for dust accumulation and carefully remove it, 

ensuring that all air cooling holes into the motor are open and free of dust deposits. 

 Install the blower in the reverse order as described above.  Remember to check the 

condition of the exhaust blower gasket AND remember to reconnect the thermal sensor 
to the top of the exhaust blower outlet before reinstalling the side panel.  