T: motor tuning, T1: induction motor auto-tuning – Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual

Page 332

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

S2-18

(3217)

Sequence Timer 4 Day

Selection

Tmr 4 Day Sel

0: Timer disabled

1: Daily

2: Mon - Fri

3: Sat - Sun

4: Monday

5: Tuesday

6: Wednesday

7: Thursday

8: Friday

9: Saturday

10: Sunday

Sets the days for which sequence timer 4 is active.

0: Timer disabled

1: Daily

2: Mon - Fri

3: Sat - Sun

4: Monday

5: Tuesday

6: Wednesday

7: Thursday

8: Friday

9: Saturday

10: Sunday

Default: 0

Range: 0 to 10

188

S2-19

(3218)

Sequence Timer 4

Selection

Tmr 4 Seq Sel

0: Digital Out Only

1: Run

2: Run - PI Disable

Sets the action that occurs when sequence timer 4 is active.

0: Digital output only

1: Run

2: Run - PI disable

Default: 0

Range: 0 to 2

188

S2-20

(3219)

Sequence Timer 4

Reference Source

Tmr 4 Ref Source

0: Operator (d1-01)

1: Operator (d1-02)

2: Operator (d1-03)

3: Operator (d1-04)

4: Terminals

5: Serial Com

Selects the frequency reference source used for running the drive

when sequence timer 4 is active (only applicable when S2-19 is

set to 1 or 2).

0: Operator (d1-01)

1: Operator (d1-02)

2: Operator (d1-03)

3: Operator (d1-04)

4: Terminals

5: Serial communication

Default: 0

Range: 0 to 5

189

u

T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance. When the drive is not accessible,

the current values of these parameters are not accessible. The default values are set by the Bypass Controller when a Bypass

Control Parameter Initialize (Z1-01 = 1, 2, or 3) command is given.

u

T1: Induction Motor Auto-Tuning

No.

(Addr.

Hex)

Name

Description

Values

Page

T1-00

(0700)

Motor 1/Motor 2 Selection

1: Motor 1

2: Motor 2

Default: 1

Range: 1, 2

114

T1-01

(0701)

<1>

Auto-Tuning Mode

Selection

Tuning Mode Sel

2: Stationary Auto-Tuning for Line-to-Line Resistance

2: Term Resistance

3: Rotational Auto-Tuning for V/f Control Energy Saving

3: V/f Engy Sav Tun

Default: 2

Range: 2, 3

114

T1-02

(0702)

Motor Rated Power

Mtr Rated Power

Sets the motor rated power as specified on the motor nameplate.

Note:

Use the following formula to convert horsepower into kilowatts:

1HP = 0.746 kW.

Default:

<2>

Min.: 0.00 kW

Max.: 650.00 kW

114

T1-03

(0703)

Motor Rated Voltage

Rated Voltage

Sets the motor rated voltage as specified on the motor nameplate.

Default: 200.0 V

<3>

Min: 0.0
Max: 255.0

<3>

114

T1-04

(0704)

Motor Rated Current

Rated Current

Sets the motor rated current as specified on the motor nameplate.

Default:

<2>

Min.: 10% of drive

rated current

Max.: 200% of

drive rated current

115

T1-05

(0705)

Motor Base Frequency

Rated Frequency

Sets the rated frequency of the motor as specified on the motor nameplate.

Default: 60.0 Hz

Min.: 0.0

Max.: 240.0

115

T1-06

(0706)

Number of Motor Poles

Number of Poles

Sets the number of motor poles as specified on the motor nameplate.

Default: 4

Min.: 2

Max.: 48

115

T1-07

(0707)

Motor Base Speed

Rated Speed

Sets the rated speed of the motor as specified on the motor nameplate.

Default: 1750 r/min

Min.: 0

Max.: 14400

115

B.12 S: Special Application

332

YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual