Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 317

Advertising
background image

9 Troubleshooting

9.1.2 Troubleshooting of Alarms

9-20

A.E50:
MECHATROLINK

Synchronization Error

WDT data of host controller was

not updated correctly.

Check the WDT data updating for

the host controller.

Update the WDT data at the host

controller correctly.

A SERVOPACK fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E51:
MECHATROLINK

Synchronization

Failed

WDT data of host controller was
not updated correctly at the syn-

chronization communications
start, and synchronization com-
munications could not start.

Check the WDT data updating for
the host controller.

Update the WDT data at the host
controller correctly.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still

occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E60:
MECHATROLINK

Communications error
(Reception error)

MECHATROLINK wiring is
incorrect.

Check the MECHATROLINK wir-
ings.

Correct the MECHATROLINK wir-
ing.
Connect the terminator correctly.

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite
core on the MECHATROLINK
communications cable.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E61:
MECHATROLINK

Transmission Cycle

Error
(Synchronization
interval error)

MECHATROLINK transmission
cycle fluctuated.

Check the MECHATROLINK
transmission cycle setting.

Remove the cause of transmission
cycle fluctuation at host controller.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still

occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E71:
Safety Option Module

Detection Failure

The connection between the
SERVOPACK and the safety
option module is faulty.

Check the connection between the
SERVOPACK and the safety option
module.

Correctly connect the safety option
module.

The safety option module was
disconnected.

Execute Fn014 (Resetting configu-
ration error of option module) with
using the digital operator or Sig-
maWin+ and turn the power supply
OFF and then ON again.

A safety option module fault
occurred.

Replace the safety option module.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

A.E72:
Feedback Option

Module Detection

Failure

The connection between the

SERVOPACK and the Feedback

Option Module is Faulty.

Check the connection between the

SERVOPACK and the Feedback

Option Module.

Correctly connect the Feedback

Option Module.

The Feedback Option Module
was disconnected.

Execute resetting configuration

error in option modules (Fn014) and

turn the power supply OFF and then

ON again.

A Feedback Option Module fault

occurred.

Replace the Feedback Option Mod-

ule.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising