10.1 List of Parameters

10-3

10

Ap

pend

ix

10.1.2 Parameters

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Pn000

2

Basic Function Select Switch 0 0000 to 00B3

0000

After restart

Setup

Pn001

2

Application Function Select
Switch 1

0000 to 1122

0000

After restart

Setup

Direction Selection

Reference

Section

0

Sets CCW as forward direction.

4.3.1

1

Sets CW as forward direction. (Reverse Rotation Mode)

2 to 3

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Servomotor power OFF or Alarm Gr.1 Stop Mode

Reference

Section

0

Stops the servomotor by applying DB (dynamic brake).

4.3.5

1

Stops the servomotor by applying DB and then releases DB.

2

Makes the servomotor coast to a stop state without using the DB.

Overtravel (OT) Stop Mode

Reference

Section

0

Stops in accordance with the setting of Pn001.0.

4.3.2

1

Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to servolock state.

2

Sets the torque of Pn406 to the maximum value, decelerates the servomotor to a stop,
and then sets it to coasting state.

AC/DC Power Input Selection

Reference

Section

0

Applicable to AC power input: Input AC power supply through L1, L2, and L3
terminals.

3.1.4

1

Applicable to DC power input: Input DC power supply between B1/ + and

−2, or input

DC power supply between B1/ + and

−.

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.