2 warning displays, 1 list of warnings – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - MECHATROLINK-II Communications Reference User Manual

Page 320

Advertising
background image

9.2 Warning Displays

9-23

9

Trou

blesh

ooting

9.2 Warning Displays

The following sections describe troubleshooting in response to warning displays.

The warning name and warning meaning output are listed in order of the warning numbers in 9.2.1 List of

Warnings.

The causes of warnings and troubleshooting methods are provided in 9.2.2 Troubleshooting of Warnings.

9.2.1 List of Warnings

This section provides list of warnings.

∗1. Use Pn008.2 to activate or not the warning detection.

∗2. Use Pn800.1 to activate or not the warning detection.

∗3. Use Pn008.1 to activate or not the warning detection.

Warning

Number

Warning Name

Meaning

A.900

*1

Position Error Overflow

Position error exceeded the parameter setting
(Pn520

×Pn51E/100).

A.901

*1

Position Error Overflow

Alarm at Servo ON

When the servomotor power is ON, the position error exceeded the parameter

setting (Pn526

×Pn528/100).

A.910

*1

Overload

This warning occurs before the overload alarms (A.710 or A.720) occur. If
the warning is ignored and operation continues, an overload alarm may occur.

A.911

*1

Vibration

Abnormal vibration at the motor speed was detected. The detection level is
the same as A.520. Set whether to output an alarm or warning by the vibra-
tion detection switch (Pn310).

A.920

*1

Regenerative Overload

This warning occurs before the regenerative overload alarm (A.320) occurs.
If the warning is ignored and operation continues, a regenerative overload
alarm may occur.

A.921

*1

Dynamic Brake Overload

This warning occurs before dynamic brake overload alarm (A.731) occurs. If
the warning is ignored and operation continues, a dynamic brake overload
alarm may occur.

A.930

*1

Absolute Encoder Battery

Error

This warning occurs when the voltage of absolute encoder’s battery is low-
ered.

A.94A

*2

Data Setting Warning 1

(Parameter Number Error)

Incorrect command parameter number was set.

A.94B

*2

Data Setting Warning 2

(Out of Range)

Command input data is out of range.

A.94C

*2

Data Setting Warning 3

(Calculation Error)

Calculation error was detected.

A.94D

*2

Data Setting Warning 4

(Parameter Size)

Data size does not match.

A.94E

*2

Data Setting Warning 5

(Latch Mode Error)

Latch mode error is detected.

A.95A

*2

Command Warning 1

(Unsatisfying Command)

Command was sent although the conditions for sending a command were not
satisfied.

A.95B

*2

Command Warning 2

(Non-supported Command) Unsupported command was sent.

A.95D

*2

Command Warning 4

(Command Interference)

Command, especially latch command, interferes.

A.95E

*2

Command Warning 5

(Subcommand Disable)

Subcommand and main command interfere.

A.95F

*2

Command Warning 6

(Undefined Command)

Undefined command was sent.

A.960

*2

MECHATROLINK
Communications Warning

Communications error occurred during MECHATROLINK communications.

A.971

*3

Undervoltage

This warning occurs before undervoltage alarm (A.410) occurs. If the warn-
ing is ignored and operation continues, an undervoltage alarm may occur.

A.9A0

*1

Overtravel

Overtravel is detected while the servomotor power is ON.

Advertising