Page 23

Switched Meter Addressing (Meter Bridges only)

The Switched meter defaults to displaying whatever source is routed to Monitor In. When bus 0 is
turned on for the Monitor Meter in device, the meter will switch to whatever source is routed to the

Monitor Meter In.

Monitor Meter In Device Numbers:

Port (Surface) Number

Device Number

1

2c

2

54

3

6a

In Command Builder, sources should be routed to d[Port1 Monitor Meter In] (or
appropriate port number) using the Alt+D pick list. Command Builder will translate this into the

appropriate hex device number.

Meter Bridge On Air and Mic Live Tally Lamps

Two tally LEDs are provided on the ROC-SMETER and ROC LMETER. The Mic Live tally may be

used to tell the operator that the mic is on. The On Air tally may be used to tell the operator that
the console has been switched to air. The bus number of the Mic Live LED is 17 and the On Air

LED is 18. The device numbers are in the chart below.

Device Numbers for Mic Live and On Air Tally Lamps

Port (Surface) Number

Device Number

1

28

2

4F

3

63

Because these LEDs are on the same device number as console GPI outputs, an easy way to
program the Mic Live lamp is to enter 117 into the Mute Tally box for each Mic on port 1. For port

2 consoles, use 217. For port 3 consoles, use 317.