Ms-pae series inverters router, 0 installation – Magnum Energy MP Extension Box (MPX Series) User Manual

Page 27

Advertising
background image

3.0 Installation

© 2011 Magnum Energy, Inc.

23

AC OUTPUT

(from Master)

AC INPUT (to Master)

Master (MA)

Slave (SL1)

MPXS-30D

MPSL-30D Enclosure

Master Inverter AC

INPUT Breaker

Slave 1 Inverter AC

INPUT Breaker

AC INPUT (to Slave)

AC OUTPUT (from Slave)

Red

Black

Green

Red

Black

Black

Red

Green

Red

Black

White

Red w/ Stripe

Black w/ Stripe

White

Red w/ Stripe

Black w/ Stripe

MS-PAE Series Inverters

Router

RED w/STRIPE

BLACK w/STRIPE

WHITE

RED

BLACK

GREEN

WIRE

TO MPSL-30D

:

FROM INVERTER

:

AC INPUT

AC OUTPUT

AC OUTPUT

AC OUTPUT

AC INPUT

AC INPUT

INV HOT 2 OUT busbar

INV HOT 1 OUT busbar

AC NEUTRAL busbar

GROUND busbar

AC INPUT breaker

AC INPUT breaker

MA

SL1

Figure 3-18a, MPXS-30D / MPSL-30D Inverter AC Wiring

Advertising