EMI CAC User Manual

Page 28

Advertising
background image

www.enviromaster.com

CAC Cassette Evaporator

28

CAC ELECTRICAL SPECIFICATIONS

Model #

Fan Motor

Elect Heat

Total

AMPS

Min

Volt M.C.A.

HACR

BRKR

Volts/HZ/PH

RLA

H.P.

K.W. AMPS

Small Cabinet 09/12

CAC09/12

208/230/60/1

0.35

1/10

0.4

197

0.5

15

CAC09/12

208/230/60/1

0.35

1/10

1.5

6.52

6.9

197

8.6

15

Medium Cabinet 18/24

CAC18/24

208/230/60/1

0.55

1/8

0.6

197

0.7

15

CAC18/24

208/230/60/1

0.55

1/8

3

13.04

13.6

197

17.0

20

Large Cabinet 30/36

CAC30/36

208/230/60/1 0.5, 0.5 1/10, 1/10

1.0

197

1.2

15

CAC30/36

208/230/60/1 0.5, 0.5 1/10, 1/10

5

21.74

22.7

197

28.3

30

S1C

Side

Discharge

CAC CASSETTE SYSTEM MATCHES

CAC

CAC ELECTRICAL SPECIFICATIONS

NOTE: Due to EMI’s ongoing product development program, all designs and specifications

are subject to change without notice.

S2C

Side

Discharge

COOLING SYSTEMS WITH CASSETTE UNITS

Condenser Cassette

Btuh SEER SHR

EER

Ref.

S1CA9

CACA12

9,000

13.0

.79

11.7

R22

S1CA2

CACA12

12,000

13.0

.72

12.2

R22

S1CA8

CACA24

18,000

13.0

.76

12.3

R22

S1CA4

CACA24

23.000

13.0

.67

11.8

R22

S1CA3

CACA36

30,000

13.5

.82

12.5

R22

S1CA6

CACA36

36,000

13.0

.74

12.6

R22

COOLING

SYSTEMS WITH S2C SIDE DISCHARGE

Cassette

Condenser

Btuh

SEER

SHR

EER

Ref.

CACA12

S2CA99

18,000

13.0

.81

11.7

R22

CACA12

S2CA22

23,000

13.0

.74

11.8

R22

CACA12

S2CA92

21,000

13.0

.77

11.8

R22

Advertising