6 alarm input / output installation, No contact alarm input connection: descriptions – EverFocus EDR-1640 User Manual

Page 24

Advertising
background image

2.6 Alarm input / output installation

The EDR920/1640 alarm inputs can be used for recording start or recording rate adjustment.

Furthermore, alarm reactions such as camera switching to monitors, buzzer, e-mail and network alarm

are available. An alarm output relay can be switched if required.

EDR920 provides 9 alarm inputs, EDR1640 provides 16. All inputs are programmable NO/NC.

Inputs have to be switched through dry contacts.

The 4 output relays provide a dry NO/NC contact.

All settings are programmed in the ALARM menu.

Use either the 37-pin Sub-D plug or the included adaptor board for connection.

NC contact alarm input connection:

Output relay in idle state:

DVR

PIN #

NAME

PIN #

NAME

1

GND

19

GND

2

ALM 1

20

ALM-NC0

3

ALM 2

21

ALM-NO0

4

ALM 3

22

ALM-COM0

5

ALM 4

23

ALM-NC1

6

ALM 5

24

ALM-NO1

7

ALM 6

25

ALM-COM1

8

ALM 7

26

ALM-NC2

9

ALM 8

27

ALM-NO2

10

ALM 9

28

ALM-COM2

11

ALM 10

29

ALM-NC3

12

ALM 11

30

ALM-NO3

13

ALM 12

31

ALM-COM3

14

ALM 13

32

ALMRSTO

15

ALM 14

33

REC

16

ALM 15

34

GIN1O

17

ALM 16

35

DISKFULL

18

GND

36

GO1

Pin assignment Sub-D plug

Pin assignment adaptor board

HOST

PIN #

NAME

PIN #

NAME

1 GND 21 GND

2 ALMIN

1 22 ALM_NC1

3 ALMIN

2 23 ALM_NO1

4 ALMIN

3 24 ALM_COM1

5 ALMIN

4 25 ALM_NC2

6 ALMIN

5 26 ALM_NO2

7 GND 27

ALM_COM2

8 ALMIN

6 28

GND

9 ALMIN

7 29 ALM_NC3

10 ALMIN

8 30 ALM_NO3

11 ALMIN

9 31 ALM_COM3

12 ALMIN

10 32

ALM_NC4

13 GND 33 ALM_NO4

14 ALMIN

11 34 ALM_COM4

15 ALMIN

12 35

GND

16 ALMIN

13 36

ALMRST

17 ALMIN

14 37

REC_IN

18 ALMIN

15 38

SPARE_IN

19 ALMIN

16 39 DISK_FULL

20 GND 40

SPARE_OUT

NO contact alarm input connection:

Descriptions:

ALMINxx:

Alarm input xx (1~16)

GND:

common ground for alarm inputs

ALM_COMx: output relay x , contact root
ALM_NOx:

output relay x , NO contact

ALM_NCx:

output relay x , NC contact

ALMRST:

Alarm reset, control input for alarm

reset, for dry NO contact

towards GND

DISKFULL: OC output contact for signal

„HDD full“, switches to GND

REC_IN:

Control contact for recording start

SPARE_IN / OUT: reserved

23

Advertising