2 hdd temp – EverFocus EDR-1640 User Manual

Page 51

Advertising
background image

The enduring HDD temperature surveillance guarantees an alarm reaction in case the

threshold value is exceeded.

There may be several reasons for HDD temperature excess:

- Exceedance of the max. tolerable ambient temperature (40

°C), e.g. upon installation in

an electrical cabinet with inadequate ventilation

- After-effect upon fan failure

- HDD defect

3.11.2 HDD TEMP.

50

WARNING SETUP MENU

FAN FAULT

BUZZER

ENABLE

HDD TEMP.

ALARM OUTPUT

1

NO HDD

ALARM DURATION PERMANENT

HDD FULL

NETWORK ALARM NO
EMAIL

NO

STOP RECORD

YES

(1) BUZZER:

By selecting “ENABLE”, the buzzer is activated upon HDD temperature excess.

(2) ALARM OUTPUT: Output relay activation.

1 – Output relay 1 ~ 4 (selection) switches upon alarm.
NONE – no output relay reaction upon alarm.

(3) ALARM DURATION: PERMANENT - This value cannot be changed, alarm is

automatically switched off after problem has been solved.

(4) NETWORK ALARM:

YES: Network alarm activated (for settings refer to NETWORK menu)

Network alarm reception requires optional PowerCon software.

NO: No network alarm transmission

(5) EMAIL:

YES: Alarm email transmission (for settings refer to NETWORK menu).

NO: No email alarm transmission.

(6) STOP RECORD

YES: Recording process is stopped to avoid further temperature rise

and HDD damage.
NO: Recording process continues.