3.10 RS232/RS485 MENU

48

CONTROL SETUP MENU

RS232
BAUD RATE

9600 BPS

STOP BIT

1

PARITY

NONE

DATA BIT

8

RS485
BAUD RATE

9600 BPS

STOP BIT

1

PARITY

NONE

DATA BIT

8

RS232/RS485 ID

1

PTZ PROTOCOL

EVERFOCUS

(1) RS232 BAUD RATE: RS-232 interface transmission speed. 1200, 2400, 4800, 9600, 19200

and 3840 baud can be selected.

Default setting: 9600 baud

(2) RS232 STOP BIT: Number of stop bits: 1 or 2
(3) RS232 PARITY:

Parity mode: NONE / EVEN / ODD

(4) RS232 DATA BIT: Number of data bits: 8 or 7
(5) RS485 BAUD RATE: RS-485 interface transmission speed. 1200, 2400, 4800, 9600, 19200

and 3840 baud can be selected.

Default setting: 9600 baud

(6) RS485 STOP BIT:

Number of stop bits: 1 or 2

(7) RS485 PARITY:

Parity mode: NONE / EVEN / ODD

(8) RS485 DATA BIT: Number of data bits: 8 or 7
(9) RS232/RS485 ID: RS232/RS485 address. Addressable range: 1~255.

This address complies with the device number for remote control

through keyboards EKB 500, KS KBK and KS KBJ (DEVICE No.).

(10) PTZ-PROTOCOL:

Protocol type setting for network telemetry control, available protocols:
EVERFOCUS1 (EPTZ1800 Dome),

EVERFOCUS2 (EPTZ1000/3000 Dome),

ED2200/2250 (complies with Samsung protocol SCC-641/643),

Pelco-D, Pelco-P

NOTE: Standard setting for EKB500 keyboard connection:

RS-485 Baud Rate: 9600, 1 stop bit, Parity NONE, RS232/RS485 ID = Device/DVR

Nr. at keyboard

Define the settings for DVR remote control through serial interface in the RS232/RS485

menu. Pin assignment and remote control protocol are described in appendix B and C.