3.11 WARNING MENU

49

3.11.1 FAN FAILURE

The EDR provides warning functions allowing signalling upon operation failure. Define the

alarm reactions in the WARNING menu.

Both fans provide failure detection. Define the alarm reactions upon fan failure in this menu

item:

(1)BUZZER: By selection “ENABLE”, the buzzer is activated upon fan failure.
(2)ALARM OUTPUT: Output relay activation.

1 – Output relay 1 (for EDR410/810, only one output relay is available)

NONE – no relay reaction upon alarm.

(3) ALARM DURATION: PERMANENT - This value cannot be changed, alarm is

automatically switched off after problem has been solved

(fan replacement).

(4) NETWORK ALARM:

YES: Network alarm activated (for settings refer to NETWORK menu)

Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission

(5) EMAIL:

YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.

WARNING SETUP MENU

FAN FAULT

BUZZER

ENABLE

HDD TEMP.

ALARM OUTPUT

1

NO HDD

ALARM DURATION PERMANENT

HDD FULL

NETWORK ALARM NO
EMAIL

NO