Special Applications, cont’d

PRELIMINAR

Y

MGP 464 • Special Applications

6-4

5

.

Repeat step 4 for every input on the matrix switcher that will be displayed

on the output screen via the MGP, saving the settings for each input as Input

Preset 2, 3, etc.

N

Each input preset must be saved with the same number as the input on the

matrix switcher.

6

.

Synchronize the MGP 464 to the matrix switcher as follows:
a

. Open the Windows-based control software.

b

. From the Tools menu, select Sync MGP 464 to Matrix Switcher... . The

Sync MGP 464 to Matrix Switcher window opens.

c

. In the IP Address field, enter the matrix switcher’s IP address.

d

. Click Connect To Matrix button. The switcher’s matrix size is displayed

to the right of the button, and its input-output ties are displayed in the

Matrix Status section below.

e

. From the drop-down menu in the MGP 464 Input #1 field, select the

number of matrix switcher output to which you connected the MGP’s

input 1 in step 1.

f.

Repeat step e for MGP inputs 2 through 4, making sure to select the

number of the switcher’s output connector to which you attached the

MGP input with which you are working.

g

. Click Take to tie the MGP inputs to the selected switcher outputs.

h

. Click Close to close the Sync MGP to Matrix Switcher window.

Sync MGP 464 to Matrix Switcher window with input ties to switcher