Preliminary, Pr ogramming and contr ol, cont’d – Extron electronic Multi-Graphic Processor MGP 464 DI User Manual

Page 76

Advertising
background image

SIS

Pr
ogramming and Contr

ol, cont’d

MGP 464 • Softwar

e Configuration and Contr

ol

4-24

PRELIMINARY

Command/response table for IP SIS commands (continued)

Command

ASCII (Telnet)

(host to processor)

URL Encoded (Web)

(host to processor)

Response

(Processor to host)

Additional description

Bi-directional serial data port

Send data string

E

X!

*

X1&

*

X2)

*

X2!

RS

}

X@

W

X!

%2A

X!

% %2A

X2)

%2A

X2!

RS

|

X@

Response from command

]

N

X!

= Port number (01-99).

X1&

= Time in tens of milliseconds that the MGP will wait until receipt of the first response character before terminating the command. (Default = 10 = 10 ms; max. = 32767.)

X2)

= Time in tens of milliseconds that the MGP will wait between characters being received via a serial port before terminating the current command or receive operation.

(Default = 20 = 20 ms; max. = 32767.)

X2!

= #L or #D. The letter parameter is case sensitive (requires capital D or capital L).

L = Length of the message to be received.
D = Delimiter value. A delimiter of ASCII 0A = 10D.
# = Byte count (for L) or a single ASCII character expressed in decimal form (for D).
Byte count # can be 0 - 32767; default = 0. The ASCII decimal # can be 0 - 00255; default = the byte count. A 3-byte length = 3L.
The response includes leading zeros.

X@

= Command data section. For Web encoding for

X@

, be sure to convert non-alphanumeric characters to hex numbers.

Example:

E

05 * 4 * 7 * 3L RS

}

<data> •

W05 %2A 4 %2A 7 %2A 3L RS

|

<data>

Response from command

]

N

The *

X1&

*

X2)

*

X2!

sequence is optional. If

X1&

and

X2)

are not specified, the default values are used.

Configure serial port parameters

24

E

X!

*

X2%

,

X2^

,

X2&

,

X2*

CP

}

W

X!

%2A

X2%

%2A

X2^

%2A

X2&

%2A

X2*

CP

|

Cpn

X!

Ccp

X2%

,

X2^

,

X2&

,

X2*

CP

]

Set baud rate

X2%

, parity

X2^

,

X2&

data bits,

and

X2*

stop bits for port

X!

X2%

= 300, 600, 1200, 1800, 2400, 3600, 4800,

7200, 9600, 14400, 19200, 28800, 38400,
57600, or 115200.

X2^

= odd, even, none, mark, or space.

(Only the first letter is required.)

X2&

= 7 or 8

X2*

= 1 or 2

View serial port parameters

E

X!

CP

}

W

X!

CP

|

X2%

,

X2^

,

X2&

,

X2*

CP

]

Advertising
This manual is related to the following products: