Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

(host to processor)

Response

(processor to host)

Additional description

Information requests (continued)

Query firmware version

Q

x.xx

]

View the firmware version number.

Query part number

N

60-771-01 or 60-771-02

View the MGP's part number.

View internal temperature

20S

X51(

]

View internal temperature

X51(

in degrees

Fahrenheit.

With tagged response – Verbose modes 2 and 3:
Sts20 *

X51(

]

Special functions

Output polarity

1 *

X\

#

Pol

X\

]

Set output polarity. For

X\

:

0 = H-/V- (default)
1 = H-/V+
2 = H+/V-
3 = H+/V+

Example:

1 * 2 #

Pol 2

]

H+/V– sync polarity

View output polarity

1 #

X\

]

View the current output polarity setting.

Output sync format

2 *

X\

#

Syn

X\

]

Set the output sync format. For

X\

:

1 = RGBHV
2 = RGBS
3 = RGsB
4 = YUV bi-level
5 = YUV tri-level

View output sync format

2 #

X\

]

View the current output sync format setting.

Blue mode

3 *

X%

#

Blu

X%

]

Turn blue mode on and off. For

X%

:

1 = blue mode on; 0 = blue mode off.

View blue mode status

3 #

X%

]

View the current blue mode status.

Text position

6 *

X50@

*

X50%

#

X50@

Tlc

X50%

]

Change the location of the text label to

X50%

in

window

X50@

.

X50@

= 0 through 4; 0 = all windows.

For

X50%

:

0 = None 4 = Top left
1 = Bottom left 5 = Top center
2 = Bottom center 6 = Top right
3 = Bottom right

View text position

6 *

X50@

#

X50%

]

View the text label position in window

X50@

.

Advertising