Preliminary – Extron electronic Multi-Graphic Processor MGP 464 DI User Manual

Page 77

Advertising
background image

4-25

MGP 464 • Softwar

e Configuration and Contr

ol

PRELIMINARY

Command/response table for IP SIS commands (continued)

Command

ASCII (Telnet)

(host to processor)

URL Encoded (Web)

(host to processor)

Response

(Processor to host)

Additional description

Bi-directional serial data port (continued)

Configure mode

24

E

X!

*

X2(

CY

}

W

X!

%2A

X2(

CY

|

Cpn

X!

• Cty

X2(

]

Select serial mode

X2(

for port

X!

.

X!

= 01 through 99.

For

X2(

:

0 = RS-232
1 = RS-422
N

Only the rear panel RS-232/422 port

can be configured. Therefore,

X!

= 1.

View mode

E

X!

CP

}

W

X!

CY

|

X2(

]

Configure flow control

24

E

X!

*

X3)

,

X3!

CF

}

W

X!

%02A

X3)

%02C

X3!

CF

|

Cpn

X!

• Cfl

X3)

,

X3!

]

Set flow control type

X3)

with

X3!

ms

between bytes. For

X3)

:

H = Hardware.
S = Software.
N = None (default).

X3!

= 0000 through 0001; default = 0 ms.

View flow control

E X!

CF

}

W

X!

CF

|

X3)

,

X3!

]

Configure receive timeout

24

E X!

*

X1&

*

X2)

*

X2#

*

X2!

CE

}

Set the time that the MGP will wait for a
response before terminating the command.

W

X!

%2A

X1&

%2A

X2)

%2A

X2#

%2A

X2!

CE

|

Cpn

X!

• Cce

X1&

,

X2)

,

X2#

,

X2!

CE

]

N

X1&

= Time in tens of milliseconds that the MGP will wait until receipt of the first response character before terminating the command. (Default = 10 = 10 ms; max. = 32767.)

X2)

= Time in tens of milliseconds that the MGP will wait between characters being received via a serial port before terminating the current command or receive operation.

(Default = 20 = 20 ms; max. = 32767.)

X2!

= #L or #D. The letter parameter is case sensitive (requires capital D or capital L). For

X2!

:

L = Length of the message to be received,
D = Delimiter value. A delimiter of ASCII 0A = 10D.
# = Byte count (for L) or a single ASCII character expressed in decimal form (for D).
Byte count # can be 0 through 32767; default = 0. The ASCII decimal # can be 0 through 00255; default = the byte count. A 3-byte length = 3L.
The response includes leading zeros.

X2#

= Priority Status for port

X!

receiving timeouts. For

X2#

:

0 = Use Send data string command parameters (default); 1 = Use Configure receive timeout command parameters. The response includes leading zeros.

View receive timeout

E X!

CE

}

W

X!

CE

|

X1&

,

X2)

,

X2#

,