Changing the mfx type (native mode), Using mfx with other parts (native mode) – Edirol SD-80 User Manual

Page 64

Advertising
background image

64

Controlling the SD-80 via MIDI

Changing the MFX type (Native mode)

fig.8-04_99

To change the effect type of the enhanced sounds
selected for parts 1–3, transmit the following system
exclusive message.

Address (p1 p2)

: when changing the insertion effect of part 1 = 11 00

when changing the insertion effect of part 2 = 11 20
when changing the insertion effect of part 3 = 11 40

:

Data (tt):

Effect type number
For details on effect types, refer to

"MFX parameter list"

(p. 80), and to

“Each Multi-

Effects Parameters”

(MFX_E.pdf) on the included CD-ROM. No effect is assigned to

Effect Type number 00 (THROUGH).

Checksum (ss)

:

For details on the calculation method, refer to the section

“How to calculate the

checksum”

within

“MIDI Implementation”

(MIDIImp_E.pdf) on the included CD-

ROM.

*

This is valid if the part 1--3

Part Output Assign

and

Part Output MFX Select

(p. 38) have not been changed

since a Native Reset message was received.

<Example> Specifying 14: STEREO CHORUS as the effect of an enhanced sound for part 2

fig.8-05_99

Transmit the following system exclusive data.

Using MFX with other parts (Native mode)

By transmitting the following system exclusive message, the insertion effect used by the enhanced sounds
selected for parts 1–3 can be used by other parts. The output of all parts that use that MFX will be mixed
and sent to the MFX.
• Do not change the

MFX source

of the three insertion effects after a Native Reset message is received.

• This will not work if effect type 00 (no effect: THROUGH) has been specified for the enhanced sounds

selected for parts 1–3.

• Any control performed on the MFX will apply equally to all parts that use that MFX.

fig.8-06_99

1.

Transmit

Output Select = MFX

to specify

MFX

as the

output of the part.

Address (pp)

:

when using the MFX for part 1 = 20
when using the MFX for part 2 = 21
:
when using the MFX for part 32 = 3F

F0 41 10 00 48 12 [p1 p2 06 00] [tt] [ss] F7

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

MFX Type
Number

Patch Common

MFX1

MFX Type

(1) Exclusive status
(2) ID (Roland : 41H)
(3) Device ID
(4) Model ID (SD-90 : 00H 48H)
(5) Command ID (Data set : 12H)
(6) Address
(7) Data
(8) Checksum
(9) End of Exclusive

F0 41 10 00 48 12 [11 20 06 00] [0E] [3B] F7

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

Multitimbre

Mode Part 1

MFX Type
Number

Patch Common

MFX1

MFX Type

F0 41 10 00 48 12 [10 00 pp 1F] [00] [ss] F7

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

00 (=MFX)

Part

Output
Assign