C.6 sensor information object (0x67), Sensor information object (0x67), See table c-8 – Emerson Process Management MICRO MOTION 2400S User Manual

Page 167

Advertising
background image

Configuration and Use Manual

159

Device Profile

D

e

vice Pr

ofile

In

de
x

Displa

y Codes

Men

u

s

C.6

Sensor Information Object (0x67)

83

Factory flow
signal offset at
zero flow

REAL

Get

NV

The flow signal offset at
zero flow when calibrated
at the factory

Unit = microseconds

84

Discrete event
action code

USINT

Set

V

The action that will be
performed by the event
specified in Attribute 85

• 1 = Start sensor zero
• 2 = Reset mass total
• 3 = Reset volume

total

• 4 = Reset API volume

total

• 5 = Reset ED volume

total

• 6 = Reset ED net

mass total

• 7 = Reset ED net

volume total

• 8 = Reset all totals
• 9 = Start/stop all

totals

• 18 = Increment ED

curve

• 21 = Reset GSV total

85

Discrete event
assignment

USINT

Set

NV

The discrete event that is
assigned to the action
referenced in Attribute 84

• 57 = Discrete event 1
• 58 = Discrete event 2
• 59 = Discrete event 3
• 60 = Discrete event 4
• 61 = Discrete event 5
• 251 = None

(1) Service code 0x4D.

Table C-8

Sensor Information Object (0x67) – Instance 1

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

1

Sensor serial
number

UDINT

Set

NV

The serial number of the
sensor

2

Sensor type

SHORT
STRING

Get

NV

A string that represents
the type of sensor

For example, F200,
CMF025

3

Sensor type
code

USINT

Set

NV

The type of sensor

• 0 = Curved tube
• 1 = Straight tube

Table C-7

Diagnostics Object (0x66) – Instance 1 continued

Attrib
ID

Name

Data type

Service

Mem

Description

Comments

Advertising