2 controlling totalizers and inventories, Controlling totalizers and inventories, Select – Emerson Process Management MICRO MOTION 2400S User Manual

Page 57

Advertising
background image

Configuration and Use Manual

49

Using the Transmitter

Requ

ired Co

nfi
g

u

ratio

n

O

ptio

nal

Con

fig
uration

Using the T

rans

m

itte

r

Us
ing a De

vice

Net T

o

ol

With ProLink II

To view current totals for the totalizers and inventories with ProLink II:

1. Click

ProLink

.

2. Select

Process Variables

,

API Process Variables,

or

ED Process Variables.

With a DeviceNet tool

To view current totals for the totalizers and inventories with a DeviceNet tool, see Section 7.3.3.

7.7.2

Controlling totalizers and inventories

Specific starting, stopping, and resetting functionality depends on the tool you are using.

With the display

If the required value is shown on the display, you can use the display to start and stop all totalizers
and inventories simultaneously, or to reset individual totalizers. See the flowchart in Figure 7-3. You
cannot reset any inventories with the display.

Figure 7-3

Controlling totalizers and inventories with the display

RESET

(6)(7)

Select

Scroll

STOP/START

(4)(5)

RESET YES?

Process variable

display

STOP/START YES?

Scroll

Mass total

(1)

Volume total

(1)

Scroll

Select

Yes

No

Select

Scroll

EXIT

Select

Yes

No

Select

Scroll

ED total

(1)(2)

Scroll

API total

(1)(2)

Scroll

E1--SP

(3)

E2--SP

(3)

Scroll

Scroll

(1) Displayed only if configured as a display variable.
(2) The petroleum measurement application or enhanced density application must be enabled.
(3) The Event Setpoint screens can be used to define or change Setpoint A for Event 1 or Event 2 only. These screens are displayed

only for specific types of events. To change the setpoint for an event defined on mass total, you must enter the totalizer
management menu from the mass total screen. To change the setpoint for an event defined on volume total, you must enter the
totalizer management menu from the volume total screen. See Section 8.6.3
for more information.

(4) The display must be configured to allow stopping and starting. See Section 8.9.3

.

(5) All totalizers and inventories will be stopped and started together, including API and enhanced density totalizers and inventories.
(6) The display must be configured to allow totalizer resetting. See Section 8.9.3

.

(7) Only the totalizer currently shown on the display will be reset. No other totalizers will be reset, and no inventories will be reset.

Be sure that the totalizer you want to reset is displayed before performing this reset.