Alarm

The alarm pins, labeled 1 and 2, (see figure at right)

on the rear panel of the FOX 2G Tx/Rx AV act

as a short when activated. They do not produce

any discrete on/off voltage signals but, instead,

act as an internal relay that will either connect or

disconnect an external alarm circuit.
For the FOX 2G Tx AV, the alarm state is activated

when link 2 is absent. For the FOX 2G Rx AV, the

alarm state is activated when link 1 is absent.
When power is lost, both the alarm state is

activated for both units.

N

The length of the exposed wires in the

stripping process is critical. The ideal

length is 3/16” (5 mm). Any longer and

the exposed wires may touch, causing a

short circuit between them. Any shorter and the wires

can be easily pulled out even if tightly fastened by the

captive screws.

C

Do not tin the wires. Tinned wire does not hold its

shape and can become loose over time.