Rs-232 ports, Configuration – Extron electronic FOX 2G Tx User Manual

Page 30

Advertising
background image

FOX 2G Tx/Rx AV • Configuration

Configuration

RS-232 Ports

Both the FOX 2G Tx AV and FOX 2G Rx AV have a front panel

TRS port and a rear panel captive screw port, which can provide

SIS commands to configure the tranmitter/receiver settings

when connected to a control device.
SIS commands for the FOX 2G Tx/Rx AV are shown (starting on

page 3-8).

N

The two comm ports work in parallel. However,

depending on the computer or the communication

settings, connecting to both comm ports at once may

result in one or both ports not working. Extron

recommends that only one comm port (front or back) is

used at a time.

The protocol for both ports is 9600 baud, no parity, 8 data bits,

1 stop bit, and no flow control.

N

Both RS-232 Remote and RS-232 Over Fiber signals

require fiber optic link 1 and link 2 for full functionality

(see page 3-4).

The front panel Config port uses a 2.5 mm mini jack connector.

Sleeve (Gnd)

Ring

Tip

2.5 mm TRS connector

Pin TRS

Tip

Ring

Sleeve

Function
Transmit data

Receive data

Signal ground

T

x

R

x

Figure 3-1 — Front panel RS-232 port

3-2

Advertising