Fox 2g tx/rx av • configuration – Extron electronic FOX 2G Tx User Manual

Page 31

Advertising
background image

FOX 2G Tx/Rx AV • Configuration

As an alternative to the front panel TRS port, the RS-232 Remote

port, on the rear panel, uses three connectors in a 5-pole captive

screw connector.

Function

Pin

TX

RX

Gnd

Transmit data
Receive data
Signal ground

Controlling

Device

Ground ( )

Receive (Rx)

Transmit (Tx)

Bidirectional

REMOTE

Tx Rx

Do not tin the wires!

OVER FIBER

Ground ( )

Receive (Rx)
Transmit (Tx)

Tx Rx

RS-232

Figure 3-2 — Rear panel RS-232 REMOTE port

In addition, on the rear panel, the units have RS-232 Over Fiber

pass-through ports. These ports allow RS-232 commands to be

passed from the control device to remote devices over the fiber

optic cable with speeds up to 115 kbps.

N

The FOX 2G Tx/Rx AV will not respond to, or generate

a response to, any commands passed through the

"RS-232 Over Fiber" ports. Refer to the user's manual

of the device being controlled for the appropriate SIS
commands.

Function

Pin

TX

RX

Gnd

Transmit data
Receive data
Signal ground

Ground ( )
Receive (Rx)

Transmit (Tx)

Bidirectional

Tx Rx

Do not tin the wires!

Tx Rx

REMOTE

OVER FIBER

Controlling

Device

Receive (Rx)
Transmit (Tx)

Ground ( )

RS-232

Figure 3-3 — Captive screw connection for rear
panel RS-232 OVER FIBER port