2 checking – Epson Weighing Indicator XK3190-A1+P User Manual

Page 15

Advertising
background image

X K 3 1 9 0 - A 1

+P

[ Enter] key or [weighing] key to exit. If it is incorrect, using digital keys enters

new date , then press [ Enter ] key.

(2) Under weighing status of the indicator, press [ Time ] key, and Time sign lamp is

lighted. Indicator display original Time data at this time. If it is correct, then press

[ Enter ] key or the [ weighing ] key to exit. If it is incorrect, using digital keys

enters new time data, then press [ Enter ] key.

4.8 Weight data store, check and clear

1 Data storing.
(1) After weighing display becoming stable, press [ Store ] key, At this time,

indicator will store weight value store into internal memory and accumulats it.

(2) At the same time, displaying [ LoAd ] for fifteen seconds to prompt operator.
(3) Negative or zero weight value can’t be stored.
(4) Indicator can store:total accumulated times. total accumulated weight value, and

200 groups of weighing records.

(5) When print control “Auto” is set to “ 1”, system not only auto-prints, but also

auto- stories and auto-accumulates weighing data.

2 Checking

Press [ Check ] key, to check the weight record data in internal memory of the Indicator.

Including: Total accumulating times, Total accumulating weight value, and every group of

weighing record.

Operating as following:

Step Operating

Display

Explanation

1

press [ Check ]

press [ Check ]

press [ Check ]

[ **** ]

[ H *** ]

[L ***** ]

n=Total accumulating times

H=Total accumulating weight High 3

bits

L=Total accumulating

weight low 5 bits

2

press [ Check ]

press [ Check ]

press [ Check ]

press [ Check ]

press [ Check ]

press [ Check ]

[no 001]

[ dt **** ]

[ t **** ]

[A *****]

[P ***** ]

[n ******]

First group of weighing

sign symbols record

Date (M.D)

Time (H.m)

Gross

Tare

Net

press [ check ]

………

[no 002 ]

………

The second group of weighing sigh

symbols record

☆ Checking ends, Indicator auto-returns to weighing mode, and using [weighing ] key,

you can quit checking mode.