Epson Weighing Indicator XK3190-A1+P User Manual

Page 8

Advertising
background image

X K 3 1 9 0 - A 1

+P

step Operation

Display

Explanation

8

press [ 1 ] [ 5 ]

[ 0 ] [0 ]

press [ Enter ]

[ A LoAd1]

[ d 1500 ]

Loading weight ≥ 5% Max.。

Example: 1500

After stable light is on, press [ Enter ]

key.

9 press [ Enter ]

[ noLoAd ] Confirming zero position again.

10

press [2] [0]

[0][0] [0]

press [ Enter ]

[ ALoAd2 ]

[ 20000 ]

Reloading weight on scale ≥50% Max.

It is better that this loading weight is

near the F.S. Example: 20000

After stable light is on, press [ Enter ]

key.

11 press [ Enter ]

press [ Enter ]

press [ Enter ]

[H xxxxxx ]

[L yyyyy ]

[td zzzz ]

H. L. td indicating three calibrating

coefficients . Recording them for spare

use.

12

press [ 1 ]

press [ Enter ]

[ Adr ** ]

[ Adr 01 ]

communication address (01-26)

Example: 1

13

press [ 1 ]

press [ Enter ]

[ bt * ]

[ bt 1 ]

Serial communication baud rate ( 0-4).

It respectively represents baud rate: 600,

1200, 2400, 4800, 9600.

Example: 1 (1200)

14

press [ 0 ]

press [ Enter ]

[ tF * ]

[ tF 0 ]

Serial communication Mode:

0- Continuous transmitting mode,

no receiving.

1- Command response mode,

Example: 0

15 Weighing

mode

Calibration End.

Note

: At step 6, 7, 8, 9, if press [ Weighing ] key, you can enter next step.

H. L. td indicating three calibrating coefficients .Recording them for spare use.


CAUTION!
When calibration is over, the calibration jumper must be pulled