3 Err 21 Calibrating data have been lost in RAM and EPROM, Operator must

put

in the calibration plug, then reenter the original calibration data, turn

on the indicator again or re-calibrate it.

4 Err 22 EPROM has been damaged.

5 Err 23 RAM has been damaged.

6.6 Other information indicating

1. Err 24 In normal operation, you must pull off the calibration jumper.The

indicator is under normal operation, and the calibration jumper shouldn’t be put in. If

calibration is needed, the calibration jumper should be put in at set-up. You should pull

out the calibration jump when turning off the indicator. If the indicator finds that the

calibration jump was inserted when turning on, it will display Err 24 for 6 seconds

to

prompt the operator.

2 Err 25 Illegal software, or E2PROM was damaged

.

12 groups of date constitutes of a frame

Date No. in a frame

explanation

1

02 (X ON) , start

2

+ or - ,

3

Weight date

4

Weight date

5

Weight date

6

Weight date

7

Weight date

8

Weight date

9

Decimal position, from right to left (0 – 4)

10

Checking XRL, higher 4 bits

11

Checking XRL, lower 4 bits

12

03 (X OFF) END